Ultrasonic monitoring of cement setting based on embedded sensor

Authors

  • Xianyong Pei
  • Qianqian Wang
  • Peng Zhao
  • Yinghui Lv

DOI:

https://doi.org/10.56028/aetr.9.1.246.2024

Keywords:

hydration, ultrasonic, piezoelectric, embedded, initial setting time.

Abstract

The hydration property of cement directly affects the performance index of concrete, so it is necessary to monitor the hydration setting process of cement. The aim of this paper is to monitor the process of cement hydration setting by ultrasonic wave. Ultrasonic monitoring is a kind of dynamic non-destructive testing technology, which has the advantages of real-time, on-line and continuous. In this paper, an in-situ monitoring technology of cement hydration setting based on embedded piezoelectric ceramic sensor is introduced. The monitoring results show that the amplitude change of ultrasonic signal received by the sensor can indirectly reflect the change process of cement hydration solid and liquid, especially the initial setting node has a high catching ability.

Downloads

Published

2024-01-02